山东氧氮氢分析仪厂家直销
MethodSelectionTwomethodsaredescribedinthisapplicationnote;eithermethodcanbeusedtoanalyzeiron,steel,nickel-,andcobalt-basealloys.ThePrecisionMethodisrecommendedforgeneraluseandwillprovidethebestprecisionandaccuracythroughoutthetypicalO,N,andHconcentrationsfoundinthisgroupofmetals;approximatecycletimeis3.5minutes.TheFastTrackmethodcanbeusedwherespeedofanalysisisacriticalcomponent;forexample,whenmoltenmetalisbeingsampledandresultsarerequiredintheshortestpossibletime.Thismethodwillproducesuitableresultsformostsamples;approximatecycletimeis2.25minutes.Asnotedabove,samplingandsamplepreparationarekeyelementstoaccurateO,N,andHdeterminationaswell.Itisuptotheusertodeterminewhichmethodbestmeetstheirneeds.上海禹重实业有限公司为您提供分析仪。山东氧氮氢分析仪厂家直销
![山东氧氮氢分析仪厂家直销,分析仪](https://tyunfile.71360.com/UploadFile/shyuzhongkeji/637535563513748805/5844577.png)
SamplePreparationSamplingandsamplepreparationisanimportantissuebecausetraditionalmethodsusedtoobtainsamplesforoxygenandnitrogendeterminationaredifferentfromthoserecommendedforhydrogen,especiallywhensamplingmoltenmetal.Themaindifferenceinsteelsamplingproceduresforoxygen/nitrogenandhydrogenisduetothemobilityofhydrogen.Specialprecautionsmustbeusedwhensamplingforhydrogen.Frommoltensteelandiron,asamplemustbequicklyquenchedincoldwaterandchilledinarefrigerantsuchasliquefiednitrogenoramixtureofacetoneandsolidcarbondioxideinordertoreducelossesofhydrogenfromdiffusion.Lossesofoxygenandnitrogenfromdiffusionarenotaproblem.Asamplethatistakenforhydrogenandchilledinarefrigerantcanalsobeusedforoxygenandnitrogendetermination.However,asamplethatistypicallytakenforoxygenand/ornitrogendeterminationisnotsuitableforhydrogendeterminationduetohydrogenloss(diffusion).Surfacecontaminationmustberemovedbyfilingorlightgrinding,usingcarenottooverheatthesample.上海进口分析仪厂家报价上海禹重实业有限公司分析仪服务值得放心。
![山东氧氮氢分析仪厂家直销,分析仪](https://tyunfile.71360.com/UploadFile/shyuzhongkeji/637535563813369453/4446585.png)
氧氮氢分析仪的常见故障及解决方法仪器启动时显示。没有水流。系统分析电流切断,分析停止。这是水流探测器不正常,水泵不工作,管道堵塞。将仪器的右面板取下,观察水流探测器,用手挤压补水塑料水瓶,发现水流正常,显示正常,证明水流探测器正常,管道畅通。启动循环水泵,但分析仪显示没有水流,此时可判定水泵不正常。打开水泵转子密封口,启动泵发现电机正常运转,此时关闭进水,拆下水泵,发现叶轮脱落。经了解,判定是由于外部冷却水停水,仪器内循环水温过高(水温应≤70℃),致使叶轮(叶轮材料PVC)热胀并脱轴。用粘合剂粘合叶轮后再粘于叶轮轴上,待粘合剂凝固后试车,仪器运行正常。
Instrumentcalibration/driftcorrection.a.Loginaminimumof3Standardreplicates.b.Weigha~1.000gramofacalibration/driftstandard,enterthemassandstandardidentificationintoappropriatereplicatefields.c.PresstheAnalyzebuttonontheinstrumentscreen.Afterashortdelay,theloadingheadslide-blockwillopen.d.Placethecalibration/driftstandardintotheopenportatthetopoftheloadinghead.e.PresstheAnalyzebuttonontheinstrumentscreenagain,theloadingheadslide-blockwillcloseandthelowerelectrodewillopen.分析仪,就选上海禹重实业有限公司,让您满意,期待您的光临!
![山东氧氮氢分析仪厂家直销,分析仪](https://tyunfile.71360.com/UploadFile/shyuzhongkeji/637535560118583032/7147316.png)
Procedure-SolidSamplesPreparetheinstrumentasoutlinedintheoperatorsinstructionmanual.Determinetheinstrumentblank.Loginaminimumof3Blankreplicates.PresstheAnalyzebuttonontheinstrumentscreen.Afterashortdelay,theloadingheadslide-blockwillopen.Placea502-344NickelBasketintotheloadinghead.Note:samplesusingautomationshouldbeplacedintheappropriateautoloaderpositionbeforestartingtheanalysissequence.Oncethesequencehasstarted,theautomaticanalysiswillstartandendautomatically.上海禹重实业有限公司致力于提供分析仪,欢迎新老客户来电!山西进口分析仪厂家直销
分析仪,就选上海禹重实业有限公司。山东氧氮氢分析仪厂家直销
ONH836氧氮氢分析仪高频燃烧红外检测技分析无机材料中的碳、硫含量。采用惰性气体保护熔融法,提供各种无机材料、钢铁、有色金属、硬质合金、难熔金属、陶瓷等材料中宽范围的氧氮氢同时分析。该仪器配置MSWindows®的软件接口,专为触摸屏操作定制。长期的开发研究与客户反馈相结合,这个简单方便的软件使得用户可以快速完整访问仪器控制,分析设置,故障诊断,数据报告,**提高日常分析的效率并节省用户宝贵的时间。可选的Cornerstone®Mobile软件功能,使得用户可以在手机,便携式电脑及台式电脑上便捷的访问仪器数据,分析曲线图形以及仪器的状态,实现对仪器的遥控。山东氧氮氢分析仪厂家直销
上一篇: 上海进口分析仪厂家报价
下一篇: 广东专业分析仪厂家供应